This software requires the nano54415 controller hardware. Any SureBatch manufactured after year 2020 will utilize this software. This controller software will require display software version A3. Notes about version 2.0.2: Issue: When pump is set to start at 100% from 0, the power supply tended to drop out due to heavy load as motor spins up. Solution: Added ramped motor speed change. Any time motor starts from stopped, manual or automatic, the motor does not immediately jump to target speed. It increments 10% of difference between target and stopped. This 10% speed increase happens every 100 milliseconds. After one second, the motor is at the desired speed. If motor is already running and on manual: if slower speed is requested, the speed changes without ramp. If faster speed is requested, the speed increase is ramped. Notes about version 2.0.1: This update fixes the following bug: * All outputs toggle on about 5 to 10 seconds after power on. After an additional few seconds, all outputs then toggle again.